Field note · 15 November 2026
Loading, dose and release rate: the three numbers people confuse
A lure is specified by release rate, bought by loading, and judged by dose. Mixing the three is why two programmes with the same spec get different catches.
Three numbers describe a pheromone lure, and they are routinely used as if they were one:
- Loading — how much active ingredient went into the dispenser, in milligrams. A manufacturing figure.
- Release rate — how much leaves the dispenser per day, in milligrams or micrograms. The number the insect responds to.
- Dose — the effective concentration in the air around the trap. What the insect actually experiences, and the only one of the three that varies with wind, temperature and trap design.
Two lures can carry the same loading and release at rates differing by a factor of three, because the polymer, the surface area and the volatility of the compound all matter. That is why “10 mg lure” is not a specification: it is a starting point for one.
Release rate sets the season length
Release is driven by vapour pressure and temperature, which means it follows something close to an exponential curve with temperature rather than a straight line. A dispenser that releases usefully for twelve weeks in a cool coastal season may be spent in eight weeks inland. This is the single most common reason a programme that works in one region underperforms in another with identical material.
The practical consequence: replace dispensers on a stated interval from the deployment date, not on appearance, and record the replacement in the trap register. A spent dispenser looks exactly like a fresh one.
Do the arithmetic before ordering
Total active required is not the number of traps multiplied by loading. It is:
traps × loading × replacements + development/trial allowance
For 60 traps, 10 mg loading, two dispenser changes in a season, that is 1.8 g of active — trivial in mass, but it determines whether you buy one pack or three, and whether the lot number is the same across the season. A programme that changes lot mid-season has changed its instrument mid-season.
Why more is not better
Overloading looks like insurance and behaves like a design error. It shortens the useful life (more mass, faster depletion), raises cost, and at high release rates can reduce catch by presenting a concentration the insect interprets as an unsuitable source. The response curve is not monotonic: there is an optimum, and it is usually lower than people expect.
Where a programme needs a longer season, the answer is usually a different dispenser type rather than more compound in the same one: a membrane or a larger reservoir changes the release profile, while more mass in a septum mostly changes the first two weeks.
What to ask a supplier
- Which dispenser type is this loading designed for?
- What release rate, at what temperature, over what period?
- What is the recommended replacement interval in a season like mine?
- Can the same lot cover the whole season?
If a quotation answers only the first question, it has quoted a mass, not a lure.