Skip to content

Semiochemicals for forest surveillance  ·  283 compounds in catalogue  ·  quote-based supply

[email protected] · Technical reply within 2 business days

Field note  ·  15 November 2026

Reading a certificate of analysis for a semiochemical

Assay, isomeric distribution, enantiomeric ratio and the chromatogram: four things on a CoA, and only one of them is the number most buyers look at first.

A certificate of analysis for a pheromone usually leads with an assay figure — 95%, 98%, 99%. It is also the least informative number on the page for anyone using the material in a lure.

What the numbers mean

  • Assay — the proportion of the material that is the named compound, by the stated method. Says nothing about which isomer.
  • Isomeric distribution — the split between geometric isomers, e.g. (E)- and (Z)-11-tetradecenal. This is the number that predicts lure behaviour.
  • Enantiomeric ratio — the split between optical isomers, e.g. (S)- and (R)-ipsenol. Relevant for a subset of compounds, and decisive for those.
  • Chromatogram — the trace behind the figures. Its value is that a receiving laboratory can reproduce the interpretation instead of trusting it.

Why geometry beats purity here

Consider two lots of (E)-11-tetradecenal: one at 98% assay with 4% of the (Z) isomer present, one at 95% assay with 0.5% (Z). The second is the better lure material, and the first will be quoted at a higher price because the assay figure looks better. In a blend where the (E)/(Z) ratio carries the species message, the difference is not cosmetic: it changes which moth the trap catches.

The same logic applies to codlemone ((E,E)-8,10-dodecadien-1-ol) and to the diene acetates, where the number of possible isomers multiplies the ways a “pure” material can still be wrong.

Reading the method

An assay by GC area percent assumes all components respond equally, which they do not — a saturated impurity can be over- or under-stated. An internal standard method corrects for this. If a certificate does not state which was used, the figure cannot be compared with another supplier’s figure, and a 2% difference may be pure method artefact.

Three things worth rejecting

  1. A certificate with no isomer data for a compound whose geometry matters. The material is under-specified, not necessarily bad.
  2. An assay figure with no method and no chromatogram — unverifiable by design.
  3. A certificate that matches an old lot number, or a lot number that does not appear on the packing list.

Retained samples

Ask for a retained sample to be held for a stated period. A trap series that behaves oddly in its third season is nearly impossible to diagnose without the material that produced it, and a retained sample converts an argument into a re-test.

Working on a programme like this? Send the species, the trap count and the flight window — the technical desk replies with a blend, a dispenser and a packing option. Send a brief.

Next step

Send the target, the blend and the deadline. We reply with a specification.

Programme design, blend ratios, dispenser selection and documentation for a tender — all handled by the same desk that ships the material.